- #HOW TO WIPE A HARD DRIVE WITH LSI MEGARAID STORAGE MANAGER OFFLINE#
- #HOW TO WIPE A HARD DRIVE WITH LSI MEGARAID STORAGE MANAGER WINDOWS#
Right Click Failed Drive, select 'Mark Drive As Missing', check 'Confirm', click 'Yes'.
#HOW TO WIPE A HARD DRIVE WITH LSI MEGARAID STORAGE MANAGER WINDOWS#
What we do with MSM in Windows when it is installed is.
#HOW TO WIPE A HARD DRIVE WITH LSI MEGARAID STORAGE MANAGER OFFLINE#
Before this patch, StorCLI will need to be downloaded and added to QRadar. The drive should still have showed for you to mark offline - but I think thats where the issue is as the controller is still expecting it to be there even if failed. StorCLI was added to QRadar in 7.4.0 Fix Pack 1. The StorCLI utility is required to modify the controller's PI state. In order for the drive to rebuild, PI needs to be disabled. Protection Information (PI) adds an extra eight bytes of information to the 512-byte sectors typical of enterprise hard drives. Note: You might have to escape the brackets "" as "\". opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ShowProg -PhysDrv -a0 To check status on the rebuilding status, run this command:.and male on a device (hard disk, controller jmicron generic scsi disk. Started rebuild progress on device encl 8 slot 2 scanner, and so on ) optical or tape media), RAID controllers and storage. opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -Start -PhysDrv -a0 To start rebuilding the drive run this command:.Note: Should you see a message similar to this while running step #4Īdapter: 0: Failed to replace Missing PD at Array 0, Row 3.ĭo the steps in the section for PI Support But I managed to find a spare 2.5' 60gig drive lying around so I connected it to the raid controller and loaded up Unraid. Where 8 and 2 in are the Enclosure Device ID and slot number, 0 in Array0 is the array number, 3 in row3 is the number of the drive in the RAID array, and 0 in a0 represents the adapter.Īdapter: 0: Missing PD at Array 0, Row 3 is replaced. The reason I didn't load Unraid to try yet was I am yet to purchase the drives I'm going to put on the server. Determine and secure the current state of an array label the drives, wires, cables, ports, controller configuration, etc. Follow each step accordingly in order to avoid losing data: Step 1. opt/MegaRAID/MegaCli/MegaCli64 -PdReplaceMissing -PhysDrv -Array0 -row3 -a0 This guide should help you to rebuild a failed RAID array. Place the missing drive into the RAID array and run this command:.opt/MegaRAID/MegaCli/MegaCli64 -pdgetmissing -aALL
![how to wipe a hard drive with lsi megaraid storage manager how to wipe a hard drive with lsi megaraid storage manager](http://www.allhdd.com/images/detailed/694/LSI_Logic-9280-8E.jpg)